Thermal Energy Consumption Assessment in a Fluid Milk Plant

Table 2.

Stream data.

Stream

m

(kg/h)

cp

(kJ/kgoC)

CP=m•cp

(kJ/hoC)

Ti

(oC)

Tf

(oC)

ΔH

(kJ/h)

H1

5,256

3.93

20,656

27

7

413,122

H2

5,256

3.93

20,656

78

6

1,487,238

C1

5,256

3.93

20,656

7

32

516,402

C2

5,256

3.93

20,656

32

78

950,180

C3

7,200

4.19

30,170

28

85

1,719,576