Thermal Energy Consumption Assessment in a Fluid Milk Plant
Table 2.
Stream data.
| Stream | m (kg/h) | cp (kJ/kgoC) | CP=m•cp (kJ/hoC) | Ti (oC) | Tf (oC) | ΔH (kJ/h) | | H1 | 5,256 | 3.93 | 20,656 | 27 | 7 | 413,122 | | H2 | 5,256 | 3.93 | 20,656 | 78 | 6 | 1,487,238 | | C1 | 5,256 | 3.93 | 20,656 | 7 | 32 | 516,402 | | C2 | 5,256 | 3.93 | 20,656 | 32 | 78 | 950,180 | | C3 | 7,200 | 4.19 | 30,170 | 28 | 85 | 1,719,576 |
|
|