Quantifying 64 drugs, illicit substances, and D- and L- isomers in human oral fluid with liquid-liquid extraction

Table 10.

LC-MS/MS conditions for the three assays on a single oral fluid sample.

P63

 

THC

 

D- and L-

Scan type

MRM

 

MRM

 

MRM

Ion source

Turbo spray

Turbo spray

Turbo spray

Probe position

X = 5.15, Y = 5.4

X = 5.15, Y = 6.40

X=5.00, Y=5.2

Polarity:

Positive

Negative

Positive

Run duration

8 min

1.5 min

11 min

Settling time (msec)

5

0

0

Pause time (msec)

5

5.0007 msec

7.007 msec

Curtain gas

35

20

35

CAD gas

8

4

4

ISV (V)

5000

-4000

5000

Temperature (°C)

500

400

500

Ion Source Gas 1 (GS1)

50

50

50

Ion Source Gas 2 (GS2)

50

60

50

Q1/Q3 resolution

unit/unit

unit/unit

unit/unit

CEM (V)

 

2600

 

2400

 

2600

Note: multiple reaction monitoring (MRM); collision gas (CAD); ion source voltage (ISV); channel electron multiplier (CEM)