Back to Article
Performance Evaluation of Filter Cloth Washing Water Recycling at SOMAÏR, Niger
Research Journal of Ecology and Environmental Sciences
| Vol 6, Issue 1
Table 4. Averageflow rates of the differentflows entering and leaving the filtration workshop
| Origin of water in the filtration workshop | Daily average month of May (with recycling) | Daily average month of June (without recycling) | |
| Total filtration consumption | 2486 m3 | 2993 m3 | |
| Appoint S3116 | 625 m3 | 1467 m3 | |
| Water Washing fabric FA, FB/FD | 1600 m3 | 1497 m3 | |
| Water Slide FA/FB | 229 m3 | 219 m3 | |
| Water FD Slide | 24 m3 | 24 m3 | |
| Water Vacuum Boxes FA/FB | 192 m3 | 166 m3 | |
| Water Vacuum Box FD | 25 m3 | 23 m3 | |
| Water Rings Liquid FA, FB/FD | 535 m3 | 409 m3 | |
| Rising water FA | 485 m3 | 470 m3 | |
| Rising water FB | 512 m3 | 484 m3 | |
| Water to Drainer | 1009 m3 | 893 m3 | |
| Drainer water to D1 | 920 m3 | 0 m3 | |
| Total water filtration to pit 3Residual | 1046 m3 | 844 m3 | |
| Recycled water at Pit 2 | 764 m3 | 628 m3 | |
| Recycled water Basin 10000 | 1748 m3 | 1352 m3 | |
| Other | Water cleaning | 806 m3 | 682 m3 |
| Low-pressurecloth washing | |||