Table 5. Inter-assaymeans and standard deviation (SD) of validation samples
| Drug / Metabolite | LLOQ | %CV | %E | LQC | %CV | %E | MQC | %CV | %E | HQC | %CV | %E |
| D-Amphetamine | 2.7 ± 0.5 | 17.09 | 9.6 | 7.8 ± 0.4 | 6.95 | 3.8 | 296.3± 7.9 | 2.67 | -1.2 | 898.6 ± 21.0 | 2.34 | -0.2 |
| L-Amphetamine | 2.8 ± 0.3 | 9.9 | 13.7 | 7.6 ± 0.6 | 8.34 | 0.8 | 293.4 ± 10.9 | 3.71 | -2.2 | 866.6 ± 25.7 | 2.76 | -3.7 |
| D-Methamphetamine | 2.5 ± 0.5 | 19.48 | -0.5 | 7.5 ± 0.7 | 9.88 | -0.3 | 286.1 ± 15.2 | 5.3 | -4.6 | 834.2 ± 59.3 | 7.11 | -7.3 |
| L-Methamphetamine | 2.6 ± 0.4 | 14.24 | 2.4 | 7.9 ± 0.6 | 7.57 | 5.6 | 323.4 ± 19.7 | 6.09 | 7.8 | 904.2 ± 59.3 | 6.56 | 0.5 |
| Target (ng/ml) | 2.5 |
|
| 7.5 |
|
| 300 |
|
| 900 |
|
|