Table 4. List of geometrical properties, cross sectionaldimensions and impact loading conditions for CFDST specimens by [19].
| Simula-tion number | Speci-men Tag number | Outer 1st layer Stainless Steel tube | Inner 2nd layer Carbon Steel tube | Inner 3rd layer Carbon Steel tube | L (mm) | Ax-ially Loaded | Magni-tude of axi-al load (kN) | H (m) | M0 (kg) | E0 (kJ) | |||
| D (mm) | ts (mm) | D (mm) | ts (mm) | D (mm) | ts (mm) | ||||||||
| 1 | L-3-0-a | 114 | 1.88 | 48 | 2.52 | N/A | N/A | 1800 | No | 0 | 3 | 203.7 | 6 |
| 2 | L-3-0-b | 114 | 1.88 | 48 | 2.52 | N/A | N/A | No | 0 | 3 | 6 | ||
| 3 | L-5-0.5-a | 114 | 1.88 | 48 | 2.52 | N/A | N/A | Yes | 343 | 5 | 10 | ||
| 4 | L-5-0.5-b | 114 | 1.88 | 48 | 2.52 | N/A | N/A | Yes | 343 | 5 | 10 | ||
| 5 | L-7-0.3-a | 114 | 1.88 | 48 | 2.52 | N/A | N/A | Yes | 206 | 7 | 14 | ||
| 6 | L-7-0.3-b | 114 | 1.88 | 48 | 2.52 | N/A | N/A | Yes | 206 | 7 | 14 | ||
| 7 | M-3-0.5-a | 114 | 1.88 | 76 | 2.01 | N/A | N/A | Yes | 317 | 3 | 6 | ||
| 8 | M-3-0.5-b | 114 | 1.88 | 76 | 2.01 | N/A | N/A | Yes | 317 | 3 | 6 | ||
| 9 | M-5-0.3-a | 114 | 1.88 | 76 | 2.01 | N/A | N/A | Yes | 190 | 5 | 10 | ||
| 10 | M-5-0.3-b | 114 | 1.88 | 76 | 2.01 | N/A | N/A | Yes | 190 | 5 | 10 | ||
| 11 | M-7-0-a | 114 | 1.88 | 76 | 2.01 | N/A | N/A | No | 0 | 7 | 14 | ||
| 12 | M-7-0-b | 114 | 1.88 | 76 | 2.01 | N/A | N/A | No | 0 | 7 | 14 | ||
| 13 | H-3-0.3-a | 114 | 1.88 | 89 | 2.01 | N/A | N/A | Yes | 142 | 3 | 6 | ||
| 14 | H-3-0.3-b | 114 | 1.88 | 89 | 2.01 | N/A | N/A | Yes | 142 | 3 | 6 | ||
| 15 | H-5-0-a | 114 | 1.88 | 89 | 2.01 | N/A | N/A | No | 0 | 5 | 10 | ||
| 16 | H-5-0-b | 114 | 1.88 | 89 | 2.01 | N/A | N/A | No | 0 | 5 | 10 | ||
| 17 | H-7-0.5-a | 114 | 1.88 | 89 | 2.01 | N/A | N/A | Yes | 237 | 7 | 14 | ||
| 18 | H-7-0.5-b | 114 | 1.88 | 89 | 2.01 | N/A | N/A | Yes | 237 | 7 | 14 | ||
No Modification - Modelling the same models as [19] and analyzing them for comparing the results.
Impactor/Indenter geometry and size - drop hammer with 30mm×80mm rectangular bottom surface.