Table 6. List of geometrical properties, cross sectionaldimensions and impact loading conditions for CFDST specimens with secondproposed modification by [1-3].
| Simula-tion number | Speci-men Tag number | Outer 1st layer Stainless Steel tube | Inner 2nd layer Carbon Steel tube | Inner 3rd layer Carbon Steel tube | L (mm) | Ax-ially Loaded | Magni-tude of axi-al load (kN) | H (m) | M0 (kg) | E0 (kJ) | |||
| D (mm) | ts (mm) | D (mm) | ts (mm) | D (mm) | ts (mm) | ||||||||
| 37 | L-3-0-a-M2 | 114 | 1.88 | 48 | 2.52 | - | - | 1800 | No | 0 | 3 | 203.7 | 6 |
| 38 | L-3-0-b-M2 | 114 | 1.88 | 48 | 2.52 | - | - | No | 0 | 3 | 203.7 | 6 | |
| 39 | L-5-0.5-a-M2 | 114 | 1.88 | 48 | 2.52 | - | - | Yes | 343 | 5 | 203.7 | 10 | |
| 40 | L-5-0.5-b-M2 | 114 | 1.88 | 48 | 2.52 | - | - | Yes | 343 | 5 | 203.7 | 10 | |
| 41 | L-7-0.3-a-M2 | 114 | 1.88 | 48 | 2.52 | - | - | Yes | 206 | 7 | 203.7 | 14 | |
| 42 | L-7-0.3-b-M2 | 114 | 1.88 | 48 | 2.52 | - | - | Yes | 206 | 7 | 203.7 | 14 | |
| 43 | M-3-0.5-a-M2 | 114 | 1.88 | 76 | 2.01 | - | - | Yes | 317 | 3 | 203.7 | 6 | |
| 44 | M-3-0.5-b-M2 | 114 | 1.88 | 76 | 2.01 | - | - | Yes | 317 | 3 | 203.7 | 6 | |
| 45 | M-5-0.3-a-M2 | 114 | 1.88 | 76 | 2.01 | - | - | Yes | 190 | 5 | 203.7 | 10 | |
| 46 | M-5-0.3-b-M2 | 114 | 1.88 | 76 | 2.01 | - | - | Yes | 190 | 5 | 203.7 | 10 | |
| 47 | M-7-0-a-M2 | 114 | 1.88 | 76 | 2.01 | - | - | No | 0 | 7 | 203.7 | 14 | |
| 48 | M-7-0-b-M2 | 114 | 1.88 | 76 | 2.01 | - | - | No | 0 | 7 | 203.7 | 14 | |
| 49 | H-3-0.3-a-M2 | 114 | 1.88 | 89 | 2.01 | - | - | Yes | 142 | 3 | 203.7 | 6 | |
| 50 | H-3-0.3-b-M2 | 114 | 1.88 | 89 | 2.01 | - | - | Yes | 142 | 3 | 203.7 | 6 | |
| 51 | H-5-0-a-M2 | 114 | 1.88 | 89 | 2.01 | - | - | No | 0 | 5 | 203.7 | 10 | |
| 52 | H-5-0-b-M2 | 114 | 1.88 | 89 | 2.01 | - | - | No | 0 | 5 | 203.7 | 10 | |
| 53 | H-7-0.5-a-M2 | 114 | 1.88 | 89 | 2.01 | - | - | Yes | 237 | 7 | 203.7 | 14 | |
| 54 | H-7-0.5-b-M2 | 114 | 1.88 | 89 | 2.01 | - | - | Yes | 237 | 7 | 203.7 | 14 | |
Modification 2 - (1) Filling the sandwich layer between the Outer 1st layer Stainless Steel tube and the Inner 2nd layer Carbon Steel tube with UHPFRC & (2) keeping the Inner 2nd layer Carbon Steel tube hollow without concrete fill.
Impactor/Indenter geometry and size - drop hammer with 30mm×80mm rectangular bottom surface.