Filter options

Publication Date
From
to
Subjects
Journals
Article Types
Countries / Territories
Open Access June 26, 2025

Mathematical modelling of the impact of HIV prevention strategies among female sex workers on public health in Burkina Faso

Abstract This article presents a mathematical model designed to simulate the impact of targeted interventions aimed at preventing HIV transmission among female sex workers (FSWs) and their clients, while also analyzing their effects on the health of the general population. The compartmental model distinguishes between high-risk populations (FSWs and their clients) and low-risk populations (sexually active [...] Read more.
This article presents a mathematical model designed to simulate the impact of targeted interventions aimed at preventing HIV transmission among female sex workers (FSWs) and their clients, while also analyzing their effects on the health of the general population. The compartmental model distinguishes between high-risk populations (FSWs and their clients) and low-risk populations (sexually active men and women in the general population), and links prevention efforts in high-risk groups to the evolution of the epidemic in the low-risk population. The fundamental properties of the model, such as the positivity of solutions and the boundedness of the system, have been verified, and the basic reproduction number R0 has been calculated. Finally, the stability of the model was studied using Varga’s theorem and the Lyapunov method. Simulation results show that targeted prevention among FSWs and their clients reduces HIV incidence in the general population. This framework provides a valuable tool for guiding policymakers in the design of effective strategies to combat the epidemic, especially relevant in the context of suspension of USAID funding.
Figures
PreviousNext
Article
Open Access November 01, 2023

Individual Wave Component Signal Modeling, Parameters Extraction, and Analysis

Abstract The accurate estimation of Individual Wave Components (IWC) is crucial for automated diagnosis of the human digestive system in a clinical setting. However, this process can be challenging due to signal contamination by other signal sources in the body, such as the lungs and heart, as well as environmental noise. To address this issue, various denoising techniques are commonly employed in bowel [...] Read more.
The accurate estimation of Individual Wave Components (IWC) is crucial for automated diagnosis of the human digestive system in a clinical setting. However, this process can be challenging due to signal contamination by other signal sources in the body, such as the lungs and heart, as well as environmental noise. To address this issue, various denoising techniques are commonly employed in bowel sound signal processing. While denoising is important, it can increase computational complexity, making it challenging for portable devices. Therefore, signal processing algorithms often require a trade-off between fidelity and computational complexity. This study aims to evaluate an IWC parameter extraction algorithm that was previously developed and reconstruct the IWC without denoising using synthetic and clinical data. To that end, the role of a reliable model in creating synthetic data is paramount. The rigorous testing of the algorithm is limited by the availability of quality and quantity recorded data. To overcome this challenge, a mathematical model has been proposed to generate synthetic bowel sound data that can be used to test new algorithms. The proposed algorithm’s robust performance is evaluated using both synthetic and clinically recorded data. We perform time-frequency analysis of original and reconstructed bowel sound signals in various digestive system states and characterize the performance using Monte Carlo simulation when denoising is not applied. Overall, our study presents a promising algorithm for accurate IWC estimation that can be useful for predicting anomalies in the digestive system.
Figures
PreviousNext
Article
Open Access March 30, 2023

Pulsatile Blood Flow Simulation for Subject-Specific Geometry of a Human Aortic Arch

Abstract Pulsatile blood flow in a subject-specific human aortic arch and its major branches is studied computationally for a peak Reynolds number of 1553 and a Womersley number of 22.74. The aortic geometry is constructed from the CT-scan images of a subject. The aorta has out-of-plane curvature and significant area variation along the flow direction. A physiologically representative pulsatile velocity [...] Read more.
Pulsatile blood flow in a subject-specific human aortic arch and its major branches is studied computationally for a peak Reynolds number of 1553 and a Womersley number of 22.74. The aortic geometry is constructed from the CT-scan images of a subject. The aorta has out-of-plane curvature and significant area variation along the flow direction. A physiologically representative pulsatile velocity waveform is applied as boundary condition at the inlet of the aorta. The primary velocity profiles are skewed towards the inner wall of the ascending aorta during the entire cardiac cycle. In the decelerating phase, reverse flow is noted along the inner wall and the magnitude of maximum velocity is about 50 % of the peak flow condition. Flow separation is observed in the inner wall of the ascending aorta during the decelerating and reverse flow phases of the cardiac cycle. In the accelerating phase, however, flow separation does not occur. The major observation of the present work is the existence of complex and asymmetrical vortical flow structures which are not observed either in simple curved pipes or in idealized aortic arch computational studies. The relative strength of the secondary flow with respect to the primary flow is quantified by means of Relative Secondary Kinetic Energy whose highest value is evaluated to be 1.202 occurring near the entrance of the right carotid artery during the maximum reverse flow condition. High values of wall shear stress is observed at distal of the left and right subclavian arteries, the bifurcation of brachiocephalic artery between right subclavian artery and right carotid artery, and proximal inner wall of descending aorta during the cardiac cycle. The wall shear stress at the bifurcations of the branches are low and oscillatory and generally correlates with the preferential sites for atherosclerosis. The flow structures on the aorta wall are explicitly highlighted by the limiting streamlines. The application of limiting streamlines to clearly elucidate the complex on-wall flow structures is one of the key contributions of the present study. During the decelerating and reverse flow phases several critical points are observed on the aortic wall. These complex flow structures vanish during the accelerating phase. The observations made in the present study will be helpful in creating accurate and clinically useful computational models.
Figures
Figure 7 (b)
Figure 7 (c)
Figure 7 (d)
Figure 8 (b)
Figure 8 (c)
Figure 8 (d)
Figure 9 (b)
Figure 9 (c)
Figure 9 (d)
Figure 11 (b)
Figure 11 (c)
Figure 11 (d)
PreviousNext
PDF Html Xml
Article
Open Access October 29, 2022

Measurement of conversion factor into mean glandular dose in mammography using OSL dosimeters

Abstract Background: Currently, the DRL quantity in mammography are evaluated in terms of mean glandular dose (MGD). Since the MGD cannot be measured directly, it can be obtained by calculation using the equation (D=K*g*c*s). In previous studies, the conversion factor g was calculated by Monte Carlo simulation and is not reported from actual measurements. In this study, we focused on the [...] Read more.
Background: Currently, the DRL quantity in mammography are evaluated in terms of mean glandular dose (MGD). Since the MGD cannot be measured directly, it can be obtained by calculation using the equation (D=K*g*c*s). In previous studies, the conversion factor g was calculated by Monte Carlo simulation and is not reported from actual measurements. In this study, we focused on the g-factor, which is a conversion factor to the MGD at 50% glandularity, and attempted to measure it using a nanoDot dosimeter to see if it can be used in mammography. Methods: The nanoDot dosimeters were inserted in a PMMA phantom at depths ranging from 0 cm to 6 cm in 1 cm increments, and measurements were made in three HVLs of 0.3 mmAl, 0.35 mmAl, and 0.4 mmAl HVL. The g-factor was calculated from the nanoDot dosimeter values using a conversion equation. Results and Discussion: The measured g-factors for all the HVLs were in close agreement with those of Dance et al. The values of the previous studies did not include the backscatter factor, which may have underestimated the MGD. The difference was smaller for the 0.4 mm Al. Compared to the other HVLs, the 0.4 mm Al was measured without a compression plate, which may have been influenced by the presence or absence of a compression plate. Conclusion: The nanoDot dosimeters were used to calculate g-factors. The results agreed with those of previous studies within uncertainty. This indicates that nanoDot dosimeters can be used in the mammography field.
Figures
PreviousNext
Article

Query parameters

Keyword:  simulation

View options

Citations of

Views of

Downloads of